Model 3963C
Preplumbed Sewage
Pump System
Installation, Operation, & Parts Manual
Safety Information
Carefully read and follow all safety instructions in this manual
or on pump.
indicates a hazard which, if not avoided, will
result in death or serious injury.
indicates a hazard which, if not avoided, could
result in death or serious injury.
indicates a hazard which, if not avoided, could
result in minor or moderate injury.
NOTICE
addresses practices not related to personal injury.
1. Read these rules and instructions carefully. Failure to
follow them could cause serious bodily injury and/or
property damage.
2. Check your local codes before installing. You must comply
with their rules.
Hazardous voltage. Can shock, burn, or
kill. During operation the pump is in water.To avoid fatal
shocks, proceed as follows if pump needs servicing:
3A. Disconnect power to outlet box before unplugging pump.
3B. Take extreme care when changing fuses. Do not stand in
water or put your finger in the fuse socket.
3C. Do not modify the cord and plug. When using the cord
and plug, plug into a grounded outlet only. When wiring
to a system control, connect the pump ground lead to the
system ground.
4. Do not run the pump dry. Dry running can overheat the
pump, (causing burns to anyone handling it) and will void
the warranty.
5. The pump normally runs hot. To avoid burns when
servicing pump, allow it to cool for 20 minutes after shut-
down before handling it.
6. The pump is permanently lubricated. No oiling or
greasing is required in normal operation. for overhaul, see
instructions under “Service”.
7. Vent sewage or septic tank according to local codes.
8. Do not install the basin or pump in any location classified
as hazardous by the United States National Electrical
Code (NEC), or by the Canadian Electrical Code (CEC),
where applicable.
Pump Specifications
Power Supply Required ................................................... 115V
Individual Branch Circuit Required ............................20 Amps
Maximum Liquid Temperature .............................130°F(55°C)*
Discharge Adapter ........................................................ 2 NPT
Description
The Simer Sewage Pump System, Model Number 3963C is
ideal for basement installations, pumping below-grade toilets,
and laundry facilities. It includes a submersible sewage pump,
a premium heavy duty structural foam, corrosion resistant
sump/sewage basin and lid, and a check valve for easy
installation.
This submersible pump is designed for effluent and wastewater
removal, sump drainage, dewatering and flood control.
The pump has built in thermal overload protection and
an automatic reset. The mechanical seal and ball bearings
on the motor shaft are permanently lubricated. Stainless
steel hardware and a heavy duty lift out ring allow for easy
disassembly after extended use.
The basin is used for residential, commercial, and industrial
collection of sewage, effluent drainage and seepage water. The
basin cover kit includes an inlet hub, a gas tight cover, cord
seals, gaskets, and hardware. No special tools or sealants are
required.
NOTICE: This unit is not designed for applications involving salt
water or brine! Use with salt water or brine will void warranty.
© 2011 SIM538 (Rev. 4/20/11)
Individual Switch Setting in inches (mm) Discharge
Model Motor Motor Full Branch Circuit Cord Length
Adapter
Number HP Load Amps Required (Amps) in ft. (m)
On Off Size
3963 1/2 13.0 20 10 (3.0) 16 (406) 7 (178) 2”
Pump, Motor, Switch, & Cord Specifications
293 Wright Street, Delavan, WI 53115
Phone: 1-800-468-7867
Fax: 1-800-390-5351
Web Site: SimerPump.com
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - Pump System

Model 3963CPreplumbed Sewage Pump SystemInstallation, Operation, & Parts ManualSafety InformationCarefully read and follow all safety instructions

Pagina 2 - Peformance • Installation 2

Pièces de rechange 10Pour les services des pièces ou d’assistance, appeler le service à la clientèle Simer en composant le 1 (800) 468-7867.1101112

Pagina 3 - Maintenance

Diagnostic des pannes 11Pour les services des pièces ou d’assistance, appeler le service à la clientèle Simer en composant le 1 (800) 468-7867.Déma

Pagina 4 - Repair Parts 4

Pour les services des pièces ou d’assistance, appeler le service à la clientèle Simer en composant le 1 (800) 468-7867.Garantie 12Conserver l’origi

Pagina 5 - Troubleshooting 5

Modelo 3963CSistema de bomba cloacal con conexiónManual de instalación, operación y partesInformación sobre la seguridadEs importante leer y seguir l

Pagina 6 - Warranty 6

Desempeño • Instalación 14Para refacciones o asistencia, llame a Simer Servicios al Cliente al: 1 800 468-7867Instalación Tensión peligrosa. Pue

Pagina 7 - Système de pompage d’eaux

Instalación • Operación • Mantenimiento 15Para refacciones o asistencia, llame a Simer Servicios al Cliente al: 1 800 468-786711. Instale la válv

Pagina 8 - Aucun débit

Refacciones 16Para refacciones o asistencia, llame a Simer Servicios al Cliente al: 1 800 468-7867110111213234538679 Piezas de reparación – siste

Pagina 9

Solución de problemas 17Para refacciones o asistencia, llame a Simer Servicios al Cliente al: 1 800 468-7867 Arranques repentinos. Si la corriente

Pagina 10 - AVERTISSEMENT

Garantía 18Para refacciones o asistencia, llame a Simer Servicios al Cliente al: 1 800 468-7867Guarde el recibo original para culaquier referencia

Pagina 11 - Diagnostic des pannes 11

Para refacciones o asistencia, llame a Simer Servicios al Cliente al: 1 800 468-7867 19

Pagina 12 - Garantie 12

For parts or assistance, call Simer Customer Service at 1-800-468-7867Peformance • Installation 2Installation Hazardous voltage. Can shock, burn or

Pagina 14 - Desempeño • Instalación 14

For parts or assistance, call Simer Customer Service at 1-800-468-7867Installation • Operation • Maintenance 311. Install the 2” check valve in the

Pagina 15 - Mantenimiento

For parts or assistance, call Simer Customer Service at 1-800-468-7867Repair Parts 4110111213234538679 Key No. Part Description Qty. 3963C1 Check Va

Pagina 16

For parts or assistance, call Simer Customer Service at 1-800-468-7867Troubleshooting 5 Sudden Starts. If the power is on to the pump when thermal o

Pagina 17 - Solución de problemas 17

Warranty 6For parts or assistance, call Simer Customer Service at 1-800-468-7867RETAIN ORIGINAL RECEIPT FOR YOUR RECORDS.Limited WarrantySIMER warr

Pagina 18 - Garantía 18

Modèle 3963CRenseignements généraux concernant la sécuritéLire attentivement et suivre exactement toutes les consignes de sécurité figurant dans cette

Pagina 19

Rendements • Installation 8Pour les services des pièces ou d’assistance, appeler le service à la clientèle Simer en composant le 1 (800) 468-7867.I

Pagina 20

Installation • Fonctionnement • Entretien 9Pour les services des pièces ou d’assistance, appeler le service à la clientèle Simer en composant le 1

Commenti su questo manuale

Nessun commento